Planning Network Data

<< Click to Display Table of Contents >>

Navigation:  Plan and Design >

Planning Network Data

Navigation: Plan and Design >

hm_btn_navigate_prevhm_btn_navigate_tophm_btn_navigate_next

Before hardware installation and data configuration, plan hardware configurations, network data, trunks, and phone numbers based on customer requirements.

For details, see Configuration Guide (Web Mode). Update data after communicating with the customer.

Precautions

ϒ⁄Before data planning, refer to the UScale Product Survey Guide to collect office information and complete the survey report.

ϒ⁄An E1 trunk supports a maximum of 30 voice channels, and a T1 trunk supports a maximum of 23 voice channels.

ϒ⁄The unified gateway IP address for internal communication (between boards) is 10.241.241.241:8080. If the external IP address to which the unified gateway is connected is a conflict with the IP address for internal communication occurs and the communication fails. In this case, change the unified gateway IP address for internal communication or the IP address for external communication.