OpenVox Document Center OpenVox Document Center
  • Home 
  • Products 
  • Solutions 
  • Resources 
    • Document Center 
    • Datasheets 
    • Firmwares 
    • Videos 
  • Partners 
  • Blog 
  • Company 
OpenVox Document Center OpenVox Document Center
OpenVox Document Center
  • Home 
  • Products 
  • Solutions 
  • Resources 
    • Document Center 
    • Datasheets 
    • Firmwares 
    • Videos 
  • Partners 
  • Blog 
  • Company 

VoIP Telephony Card

  • folder icon closed folder iconUser Manual
    • Analog Cards
      • A2410P/E AE2410P/E Hardware Manual
      • A400P/E Hardware Manual
      • A1610P/E AE1610P/E Hardware Manual
      • A810P/E AE810P/E Hardware Manual
      • Analog Card Software Installation Manual_Rockey
      • Analog Card Software Installation Manual_Debion
    • Digital Cards
      • D130P/E DE130P/E Hardware Manual
      • D230P/E DE230P/E Hardware Manual
      • D430P/E DE430P/E Hardware Manual
      • D830P/E DE830P/E Hardware Manual
      • D1630E DE1630E Hardware Manual
      • E1 Card Software Installation Manual_Rockey
      • E1 Card Software Installation Manual_Debion
    • X204 Hybrid Cards
      • X204P/E Hardware Manual
      • X204 Card Software Installation Manual_Debion
      • X204 Card Software Installation Manual_Rockey
    • BRI Cards
      • B400P/E BE400P/E Hardware Manual
      • B100P/E Hardware Manual
      • B800P Hardware Manual
      • B200P/E BE200P/E Hardware Manual
      • BRI Card Software Installation Manual_Debion
      • BRI Card Software Installation Manual_Rockey
    • Transcoding Cards
      • TAP100 User Manual
      • V100 User Manual
      • V100_PTMC user manual
      • V100_ETH and V100_BOX user manual
    • EOL
      • Analog Cards
        • A400E on DAHDI User Manual
        • A400M on DAHDI User Manual
        • A400P on DAHDI User Manual
        • A810E AE810E on DAHDI User Manual
        • A810P AE810P on DAHDI User Manual
        • A1610E AE1610E on DAHDI User Manual
        • A1610P AE1610P on DAHDI User Manual
        • A2410P AE2410P on DAHDI User Manual
      • Digital Cards
        • D130E/DE130E on DAHDI User Manual
        • D130P/DE130P on DAHDI User Manual
        • D230E/DE230E on DAHDI User Manual
        • D230P/DE230P on DAHDI User Manual
        • D430E/DE430E on DAHDI User Manual
        • D430P/DE430P on DAHDI User Manual
        • DE830E/D830E on DAHDI User Manual
        • DE830P/D830P on DAHDI User Manual
        • D210E/DE210E on DAHDI User Manual
        • D210P/DE210P on DAHDI User Manual
        • D410E/DE410E on DAHDI User Manual
        • D410P/DE410P on DAHDI User Manual
      • X204 Hybrid Cards
        • X204P/X204E Hybrid cards User Manual
      • BRI Cards
        • B100E on DAHDI User Manual
        • B100M on DAHDI User Manual
        • B100P on DAHDI User Manual
        • B200E /BE200E on DAHDI User Manual
        • B200M on DAHDI User Manual
        • B200P/BE200P on DAHDI User Manual
        • B400E/BE400E on DAHDI User Manual
        • B400M on DAHDI User Manual
        • B400P/BE400P on DAHDI User Manual
        • B800P on DAHDI User Manual
  • folder icon closed folder iconAPP Note
    • Enhanced CID Detection Feature in A810/1610/2410
    • Enhancing Busy Tone Detection Function in A810/1610/2410
    • How to Integrate Analog Gateway and GSM Gateway Modules in One VoxStack Box
    • Up to 32 E1 in an Asterisk Server By OpenVox D430E Telephony Cards
    • Up to 48 E1 in an Asterisk Server By OpenVox D430E Telephony Cards
  • folder icon closed folder iconFAQ
    • Analog Cards FAQ
      • Dahdi For Analog
      • Zaptel For Analog
    • BRI Cards FAQ
      • Dahdi For BRI
      • mISDN For BRI
      • Zaptel For BRI
    • E1/T1 Cards FAQ
      • Dahdi for pri
      • Zaptel for PRI
    • GSM Cards FAQ

VoIP Telephony Card

  • folder icon closed folder iconUser Manual
    • Analog Cards
      • A2410P/E AE2410P/E Hardware Manual
      • A400P/E Hardware Manual
      • A1610P/E AE1610P/E Hardware Manual
      • A810P/E AE810P/E Hardware Manual
      • Analog Card Software Installation Manual_Rockey
      • Analog Card Software Installation Manual_Debion
    • Digital Cards
      • D130P/E DE130P/E Hardware Manual
      • D230P/E DE230P/E Hardware Manual
      • D430P/E DE430P/E Hardware Manual
      • D830P/E DE830P/E Hardware Manual
      • D1630E DE1630E Hardware Manual
      • E1 Card Software Installation Manual_Rockey
      • E1 Card Software Installation Manual_Debion
    • X204 Hybrid Cards
      • X204P/E Hardware Manual
      • X204 Card Software Installation Manual_Debion
      • X204 Card Software Installation Manual_Rockey
    • BRI Cards
      • B400P/E BE400P/E Hardware Manual
      • B100P/E Hardware Manual
      • B800P Hardware Manual
      • B200P/E BE200P/E Hardware Manual
      • BRI Card Software Installation Manual_Debion
      • BRI Card Software Installation Manual_Rockey
    • Transcoding Cards
      • TAP100 User Manual
      • V100 User Manual
      • V100_PTMC user manual
      • V100_ETH and V100_BOX user manual
    • EOL
      • Analog Cards
        • A400E on DAHDI User Manual
        • A400M on DAHDI User Manual
        • A400P on DAHDI User Manual
        • A810E AE810E on DAHDI User Manual
        • A810P AE810P on DAHDI User Manual
        • A1610E AE1610E on DAHDI User Manual
        • A1610P AE1610P on DAHDI User Manual
        • A2410P AE2410P on DAHDI User Manual
      • Digital Cards
        • D130E/DE130E on DAHDI User Manual
        • D130P/DE130P on DAHDI User Manual
        • D230E/DE230E on DAHDI User Manual
        • D230P/DE230P on DAHDI User Manual
        • D430E/DE430E on DAHDI User Manual
        • D430P/DE430P on DAHDI User Manual
        • DE830E/D830E on DAHDI User Manual
        • DE830P/D830P on DAHDI User Manual
        • D210E/DE210E on DAHDI User Manual
        • D210P/DE210P on DAHDI User Manual
        • D410E/DE410E on DAHDI User Manual
        • D410P/DE410P on DAHDI User Manual
      • X204 Hybrid Cards
        • X204P/X204E Hybrid cards User Manual
      • BRI Cards
        • B100E on DAHDI User Manual
        • B100M on DAHDI User Manual
        • B100P on DAHDI User Manual
        • B200E /BE200E on DAHDI User Manual
        • B200M on DAHDI User Manual
        • B200P/BE200P on DAHDI User Manual
        • B400E/BE400E on DAHDI User Manual
        • B400M on DAHDI User Manual
        • B400P/BE400P on DAHDI User Manual
        • B800P on DAHDI User Manual
  • folder icon closed folder iconAPP Note
    • Enhanced CID Detection Feature in A810/1610/2410
    • Enhancing Busy Tone Detection Function in A810/1610/2410
    • How to Integrate Analog Gateway and GSM Gateway Modules in One VoxStack Box
    • Up to 32 E1 in an Asterisk Server By OpenVox D430E Telephony Cards
    • Up to 48 E1 in an Asterisk Server By OpenVox D430E Telephony Cards
  • folder icon closed folder iconFAQ
    • Analog Cards FAQ
      • Dahdi For Analog
      • Zaptel For Analog
    • BRI Cards FAQ
      • Dahdi For BRI
      • mISDN For BRI
      • Zaptel For BRI
    • E1/T1 Cards FAQ
      • Dahdi for pri
      • Zaptel for PRI
    • GSM Cards FAQ

B800P Hardware Manual

Estimated reading: 7 minutes 442 views

 

word image 79

  • Chapter 1 Overview
    • 1.1 Introduction of B800P
  • Chapter 2 Hardware Installation
    • 2.1 Power Supply
    • 2.2 Slot
    • 2.3 Setting Card ID
    • 2.4 Adjusting the terminal S/T interface mode
    • 2.5 Power Supply Power Setting
    • 2.6 Hardware Installation Steps
  • Chapter 3 Reference Table of Contents
    • Appendix A Hardware Specifications
    • Appendix B RJ45 Pin Assignment

Safety Instructions

 

  1. (a) The B800P is subject to specific national safety regulations during application.
  2. (a) Turn off the power before installing the B800P.
  3. (b) To prevent damage to the board by electrostatic induction, snap the card stopper to the PC with screws for grounding.
  4. (b) The electrostatic ring is essential during installation.
  5. Please follow the instruction steps.

Chapter 1 Overview

1.1 Introduction of B800P

OpenVox B800P is a PCI 2.2 compliant BRI card with 8 S/T interfaces, each interface can be set to TE or NT mode via jumpers. The B800P provides a software migration solution from ISDN technology to the new world of Voice over IP.

The B800P works well with open source operating systems such as Asterisk®, Issabel, FreeSWITCH™, Yate™, and IPPBX/IVR to deliver clear voice, and can be used as a PBX, IVR, and Voice-over-IP (VoIP) network. It can be used as a PBX, IVR, and VoIP gateway.

Typical Applications

  • High-performance ISDN BRI voice boards
  • ISDN BRI private automatic switch
  • ISDN BRI Network Routing
  • VoIP Voice Gateway
  • ISDN PBX Trunking
  • ISDN BRI Test Equipment

Key Features

  • Integrated 8 S/T interfaces
  • Support PCI 2.2 or above specification, provide 3/5V voltage
  • Single board supports four 4-pin RJ45 connectors
  • Support TE/NT mode, comes with NT mode power supply chip
  • Daisy chain PCM bus connection
  • 32-bit bus controller supports DMA data exchange at rates up to 133Mb/s
  • DTMF detection for each B-channel
  • Hardware echo cancellation for premium voice (supported by BE400)
  • Multi-party voice conference bridging
  • Fully compatible with NET ISDN, mISDN driver, DADHI and other drivers
  • ITU-T I.430 and TBR 3 certified
  • RoHS

Certified

  • CE, FCC, A-Tick
  • Issabel

Chapter 2 Hardware Installation

2.1 Power Supply

The B800P board needs only 3.3/5V from the PCI slot when working in TE mode. When working in NT mode, users need to provide external power to the board through the 12V 4-PIN D-type connector, otherwise it will not work properly.

2.2 Slots

The B800P is compatible with industry standard 32-bit 3.3V, 32-bit 5.0V, 64-bit 3.3V and 64-bit 5.0V PCI slots, and is not compatible with any type of PCI-E slots. Users should first confirm the slot type and insert the B800P vertically into any of the PCI slots. The following figure depicts the five slot shapes.

IO9GhwRMOjUpgAAAAASUVORK5CYII=

Figure 1 PCI and PCI-E Slots

2.3 Setting Card ID

If you need to install multiple B800P voice cards on one server, you need to set up the Card ID.

  • (a) The ID of the first card must be set to 0, the second card must be set to 1, and so on.
  • The first card is the one that is initialized first when the system boots. In most cases, Linux will initialize PCI devices in order, and the PCI device closest to the CPU will be initialized first. That is, if there are multiple B400/BE400s installed on the same server, the card ID of the one closest to the CPU must be set to 0.

2.4 Adjusting the terminal S/T interface mode

The interface of B800P can be set to NT or TE mode, please refer to the following figure.

  • If the interface needs to work in NT mode, the jumper should be set to connect.
  • If working in TE mode, the jumper should be set to disconnect in theory, but the B800P may be connected to some non-standard ISDN terminal devices which do not have terminal resistors, and the jumper should be set to connect in this case.

word image 82

Figure 2 B800P jumper setting

2.5 Power Supply Settings

These jumpers control whether power is supplied to the external ISDN terminal and should be set by the user according to the following prompts.

  • (a) If the port is operating in TE mode, the power jumper should be set to disconnect.
  • if the port is operating in NT mode, the power jumpers should be set to connected, but if the connected device is self-powered, then the jumpers should be set to disconnected.
  • if one of the 8 power jumpers is set to connected, then the user needs to provide external power to the board through the 12V 4-PIN D-type connector, otherwise it will not work properly.
  • PCI slots generally provide 3V/5V voltage, but some computers in which PCI slots no longer provide 5V voltage, then the voltage selection jumper should be set to 3.3V input.

2.6 Hardware installation steps

  • Turn off the computer and unplug the power cable.
  • Make sure that the jumpers are set correctly.
  • check that the Card ID is set correctly first when multiple cards are installed.
  • confirm that the slot type is PCI and insert the B800P vertically into the slot.
  • If there is a port working NT mode, insert the 12V 4-PIN D-type connector into the corresponding power connector on the board.
  • After inserting the SP124 splitter into each RJ45 port, set the ISDN phone line access to the S/T port in TE mode and the ISDN terminal access to the S/T port in NT mode.
  • Secure the board and ground it.
  • Plug in the power cord and power on.

 

Note : As long as there is a port operating in NT mode, an external power supply is required. Static loops are essential during the above operation and installation or removal of the board should only be done after power is removed. Please check the availability of ISDN line and ISDN terminal before connecting the hardware. After making sure the hardware is installed correctly, you can start the software installation.

Chapter 3 Reference Table of Contents

www.openvox.cn

www.digium.com

www.asterisk.org

www.voip-info.org

www.asteriskguru.com

Warm Tips.

If users encounter any problems during installation and use, please find answers and leave messages on OpenVox forum or wiki.

OpenVox Forum

OpenVox wiki

Appendix A Hardware Specifications

– Weight, Size

Weight(g) : 137g

Size(cm): 17.1×10.7×1.6

– Interface

Interface: 8-pin RJ45 interface, divided into two ISDN S/T interfaces via splitter

PCI : 3.3/5V, PCI 2.2 specification or above

Power connector: 12V 4-pin connector (for NT mode power supply)

-Environment

Temperature: 0 ~ 50°C (operating)

– 40 ~ 125°C (Storage)

Humidity: 10 ~ 90% non-condensing

-Power consumption

Voltage: 3.3/5V, 38V (NT mode only)

Power loss: min. 1.22W, max. 1.85W (TE)/17.6W (NT)

– Hardware and software configuration requirements

RAM 128+ MB

Linux kernel 2.4.X or 2.6.X

CPU 800+ MHZ

Appendix B RJ45 Pin Assignment

ISDN BRI has two kinds of interface: U interface and S/T interface, B800P provides four-pin S/T interface. We illustrate the pin assignments with the following two tables.

l ISDN U interface

8-pin RJ45 connector Pins Color Description
1 White/Orange N/A
2 Orange N/A
3 Orange White/Green N/A
4 Blue U interface
5 White/Blue U interface
6 White N/A
Green White/Brown -48VDC Power (optional)
White Brown -48VDC Return (optional)

The ISDN U interface is typically used in North American ISDN networks and uses a standard 8-pin RJ45 connector, but only the center two pins (4 and 5) are used, forming a two-conductor crossover. The optional -48 VDC power pin can be defined by pins 7 and 8 of the RJ-45. This can be used to power NT-1 or TE devices when needed. In most cases, the telephone company does not provide a feed.

l ISDN S/T Interface

8-pin RJ45 connector Pin Color Description
1 White/Orange N/A
2 Orange N/A
3 Orange White/Green Receive+
4 Blue Transmit +
5 White/Blue Transmit –
6 Green Receive –
7 White/Brown -48VDC Power(optional)
8 Brown -48VDC Return (optional)

The ISDN S/T interface also uses a standard 8-pin RJ45 connector, but only four of the pins (3, 4, 5 and 6) are used, forming a four-core straight-through line. Of these, 4 and 5 are used for transmit and 3 and 6 are used for receive. The optional -48 VDC power pins can also be defined by pins 7 and 8 of the RJ-45 and are used to power NT-1 or TE devices when needed.

 

 