Checking ASI Board Indicators

<< Click to Display Table of Contents >>

Navigation:  Operation and Maintenance > Administrator Guide > Routine Maintenance > Checking Equipment Indicators >

Checking ASI Board Indicators

Navigation: Operation and Maintenance > Administrator Guide > Routine Maintenance > Checking Equipment Indicators >

hm_btn_navigate_prevhm_btn_navigate_tophm_btn_navigate_next

The ASI board is an analog user interface board that provides access services for POTS phones.

Figure 1 shows the ASI board.

Figure 1 Description of ASI board indicators

U1900_mntg_image_f_u1960_mntg_00228_01

Indicators in different status represent the running status of the device. Table 1 describes the indicator status.

Table 1 Status of ASI board indicators

Indicator

PWR

Color

Status Description

Troubleshooting

Power indicator

PWR

Green

ϒ⁄Steady on: Power is supplied.

ϒ⁄Off: No power is supplied or the board is faulty.

ϒ⁄No power supply. When this occurs, check the power cable connection.

ϒ⁄Board fault. See Emergency Maintenance of the  UScale X1900 series to rectify the fault.

Running indicator

RUN

Green

ϒ⁄Blinking (4 Hz): The board is loading software.

ϒ⁄Blinking (2 Hz): The board is running normally and a user is in off-hook state.

ϒ⁄Blinking (0.5 Hz): The board is running normally and no conversation exits.

ϒ⁄Blinking (1 Hz): The communication is abnormal.

ϒ⁄Steady on: The board is incorrectly installed or faulty.

ϒ⁄Off: No power is supplied or the board is faulty.

ϒ⁄No power supply. When this occurs, check the power cable connection.

ϒ⁄Board fault. See Emergency Maintenance of the  UScale X1900 series to rectify the fault.

Alarm indicator

ALM

Red

ϒ⁄Steady on: The communication is abnormal or the board is incorrectly installed or faulty.

ϒ⁄Off: The board is running normally.

 

Parent Topic: Checking Equipment Indicators

 

 