Table 1 Physical Parameter


UCP1600

UCP2120

UCP4131

Dimension

44mm*434mm*330mm (height*width*length)

88mm*434mm*330mm (height*width*length)

176.8mm*435.8mm*330mm (height*width*length)

Weight

3.9kg (CSU-F+5*Empty panels)

5.6kg (CSU-F+11*Empty panels)

9.6kg (CSU-F+11*Empty panels+2*PSU)

Maximum Power

<64W

<170W

<340W

Input Voltage (AC power)

100V~240V AC

Input Current (AC power)

1A

2A

4A

Power Frequency (AC power)

50Hz/60Hz

Maximum Output Power (AC power)

75W

200W

400W

Feeder Voltage

-48V

User Line Distance (the diameter of the user line is 0.4mm, and the phone is not connected to parallel lines)

3.0km

Storage Temperature

-40ºC~70ºC

Long-term Working Temperature

0ºC~45ºC

Short-term Working Temperature

-5ºC~55ºC

Description:

Short-term work is defined as working for no more than 12 consecutive hours and no more than 8 days per year in aggregate.

Ambient Humidity

5%~95% RH, non-condensing

Particle Concentration in Air

Less than 180 mg/m3

 