SS7 Signaling Interface Manual
SS7 Signaling Configuration
First, the operator must provide the OPC, DPC, Firstcic, Schannel, and ISUP/TUP OPC: Originating Point Code (the point code assigned by the operator to the peer)
DPC: Destination Point Code (the point code on the operator’s end)
Firstcic: Initial Circuit Identification Code, typically 1
Schannel: Signaling Timeslot, typically 16
ISUP/TUP: Typically ISUP, rarely TUP
Port Configuration
In the Relay Settings – Endpoint Settings section, select SS7 Settings
Signaling Configuration
Link Group Settings
Point Code Format: China 7 selects 24 bits, international selects 14 bits
Source Point Code/Destination Point Code: Enter the values provided by the operator. The operator may provide decimal numbers, which need to be converted to hexadecimal and entered into the network gateway Link Settings
Signaling Channel: Provided by the operator, typically 16
Initial Circuit Identification Code: Typically 1, occasionally 0
Verification
After configuration, check the channel status; a green indicator confirms successful port setup